1 CHANNEL ECG
Introduction:
- ECG100G Is A Kind Of Single Channel Electrocardiograph, Which Features In Printing ECG Waveform By Thermal Printing System, Prompting For “Lead Off” Or “Lack Of Paper”, Multi-Language Interface, Recording ECG Waveform In
- AUTO/Manual Mode, Convenient To Operate.
Function:
- Adopt Digital Signal Processing Technology And Get High-Quality ECG Wave
- Form Via Power Frequency Filter, Baseline Filter And EMG Filter Of ECG Signal.
- Adopt High-Resolution Thermal Printing System (8 Dot/Mm), No Need For Any Adjustments. Recording Frequency: Up To 150Hz.
- Real-Time And Continuously Record Clear And Accurate ECG Waveform And Annotation Character (Including Lead Mark, Sensitivity, Paper Speed And Filter State, Etc.).
- In AUTO Mode, Finish Recording By Pressing The Button Once, Which Improves Work Efficiency.
- Multi-Language (Chinese, English, French, Italian, German, Spanish,Turkish, Russian And Kazakh) Interface And Report.
- In Optimal DC State, Up To 7-Hour Standby Time, Continuous Print Up To 4-Hour, Record Up To 150 Pieces Of ECG Waveform.
Features:
- Large LCD Display Waveform And Data
- The High-Resolution Thermal Printing Array System
- Frequency Response Is As High As 150 Hz
- Capable Of Printing Continuously On Channel Trace And Annotations Including Lead Mark And Parameter Such As Sensitivity, Paper Speed And Filter Operation Status
- High-Resolution Digital Filter Inhibits Baseline Drift Without Affecting ECG Waveform
- Floating Input Circuit Meets IEC Safety Standard
- Rechargeable Battery Supporting More Than 50 Patient Examinations
- Internal Software: GB, FR, IT, ES, DE, TR
- Manual: GB, IT (ES On Request)
Technical Specifications:
Safety Type | Class I, Type CF Applied Part, Which Has Defibrillation-Proof Applied Part |
Lead Standard | 12 Leads |
Input Way | Floating And Defibrillation Protection |
Patient Leak Current | <10µA |
Sampling Rate | 1000Hz |
A/D Conversion | 12bit |
Frequency Response | 0.05Hz~150Hz (-3dB, + 0.4dB) |
Time Constant | >3.2s |
CMRR | >60dB, >100dB (Add Filter) |
Enduring Polarization | Voltage ±500mV |
Noise Level | <15µVp-P |
Dispose Wave Data:
- EMG Interference Filter 35Hz (-3dB)
- AC Filter 50Hz/60Hz (=20dB)
Waveform Output:
Recording Way | Thermal Printing System |
Recording Paper | 50mm(W)×20m(L) |
Sensitivity | 5, 10, 20mm/MV |
Paper Speed | Auto-Record: Auto Leads ChangingRhythm Record: 25 Mm/S, 50 Mm/S
Manual-Record: 25 Mm/MV, 50 Mm/MV |
Power Supply:
AC | 110-220V, 50/60 Hz |
DC | 7.4V, 3700 MAh Rechargeable Lithium Polymer Battery Fuse |
2 Pcs F5×20mm AC Time Lag | T250mA/250V (Power Supply:220V) |
Size | 315 X 215 X 77 Mm |
Net Weight | 2.25 Kg |
Standard Accessories:
- ECG Cable – 1 Set
- Limb Electrode Clamp – 1 Set
- Chest Electrodes – 1 Set
- Ground Wire
- Power Connection
- Paper Roll
Reviews
There are no reviews yet.